Congratulations: new paper has been accepted for publication in Composite Structures.

14 April, 2015

 

 
Abstract:
 
Fiber Bragg gratings (FBG) may be used to monitor strain over the surface of a structure as an alternative technology to conventional strain gauges. However, FBG bonding techniques have still not been established to yield satisfactory surface measurements. Here, two adhesives were investigated, one with low viscosity and the other with high viscosity for bonding FBGs on glass/epoxy sandwich skins. First, instrumented elementary specimens were tested under tension. FBG strain results were analyzed together with digital image correlation (DIC) measurements. The influence of the bonding layer on the measured strain and on the integrity of the sensor was investigated by considering different regions of interest. Next, an instrumented structural sandwich beam was tested under four-point bending. FBG rosettes were compared to conventional strain gauge rosettes. The high viscosity adhesive demonstrated behaviors that affected FBG accuracy. Brittleness of the bonding layer and poor interface adhesion were observed using DIC and X-ray tomography. By contrast, the low viscosity adhesivedemonstrated satisfactory results. The FBG strain measurements appeared to be consistent with those of DIC. The accuracy is also adequate as the FBGs and the conventional strain gauges had similar results in three directions, under tension and under compression.